252
pad mode x
Sets the PAD mode.
x = 0
start up UDP PAD mode. The modem will revert to server mode once the
connection is closed. (default)
x = 1
start up TCP PAD mode. The modem will revert to server mode once the
connection is closed.
x = 2
start up UDP PAD client mode - one session. The modem will revert to
command mode once the connection is closed.
x = 3
start up TCP PAD client mode - one session. The modem will revert to
command mode once the connection is closed.
x = 4 start up persistent UDP PAD client mode
x = 5 start up persistent TCP PAD client mode
x = 6 start up Dialup Emulation over UDP mode
x = 7 start up Dialup Emulation over TCP mode
x = 8 start up PAD with the file based reporting system
x = 9 start up hybrid PAD mode (UDP)
x = 10 start up hybrid PAD mode (TCP)
Notes:
• The connection is closed if one of the following occurs:
• pad svct idle timeout expires
• pad svct maximum session timeout expires
• cmd pad reset is executed
• The connection is closed by remote host (TCP PAD only)
• If [pad ip] is set to 0.0.0.0, PAD will start in server mode. Otherwise it will start in client mode. Note that for the client modes (2, 3, 4 and 5), [pad ip]
must be different than 0.0.0.0. Note that for dialup emulation modes (6 and 7), [pad clientport] must be set.
Examples:
1. Set to TCP PAD mode :
cmd pad mode 1
See also: [PAD]
Firmware revision 1.2.0_RC7(rev.1187)