mbusm cond n b t [sid1, r1, dt1, md1, Md1] [sid2, r2, dt2, md2, Md2] [mt]
*This is command is used when CTM200 is being used as a MODBUS Master*
Set the condition that will trigger a MODBUS Master report. The conditional operator is used to indicate how all of the following parameters will be used
to determine if a report is triggered.
n = 1 to 8 MODBUS Master trigger condition number
b = 0 Conditional operator for all parameters: Off (default)
b = 1 Conditional operator for all parameters: AND
b = 2 Conditional operator for all parameters: OR
t = 0 Timeout disabled (default)
t = 1 to 65535 Timeout in seconds
sid1 = 0 Disable comparing register r1 of sid1 (default)
sid1 = 1 to 4 MODBUS Slave device ID
r1 = 0 Disable comparing register r1 of sid1 (default)
r1 = 1 to 65536 Register address in sid1
dt1 = 0 Data type: Single bit, discrete output (default)
dt1 = 1 Data type: Single bit, discrete input
dt1 = 2 Data type: 2 bytes, 16-bit register input
dt1 = 3 Data type: 4 bytes, 32-bit integer input
dt1 = 4 Data type: 4 bytes, 32-bit float input
dt1 = 5 Data type: 2 bytes, 16-bit register output
dt1 = 6 Data type: 4 bytes, 32-bit integer output
dt1 = 7 Data type: 4 bytes, 32-bit float output
md1 Low data value of r1. Data type is defined by dt1 (0 is default)
Md1 High data value of r1. Data type is defined by dt1 (0 is default)
sid2 = 0 Disable comparing register r2 of sid2 (default)
sid2 = 1 to 4 MODBUS Slave device ID
r2 = 0 Disable comparing register r2 of sid2 (default)
r2 = 1 to 65536 Register address in sid2
dt2 The same as dt1
md2 Low data value of r2. Data type is defined by dt2 (0 is default)
Md2 High data value of r2. Data type is defined by dt2 (0 is default)
mt = 0 to 65535
Maximum reporting rate in seconds (minimum time between reports) (0 is
default)
Notes:
The mt parameter must be used at the end if all other optional parameters are entered.
Examples:
1. Send MODBUS Master report 1 every 60 seconds :
cmd mbusm cond 1 1 60