Página 1 - Wikiprint Book

Wikiprint BookTitle: CTM-200 Command ReferenceSubject: CTM-200 Documentation: Command ReferenceVersion:Date: 2013-09-12

Página 2 - Table of Contents

WikiPrint - from Polar Technologies10accelreport n r1 [r2] [r3] [r4] [r5] [r6] [r7] [r8]This command sets the report(s) to be used for an acceleration

Página 3

WikiPrint - from Polar Technologies1005 RSq:0.124916 LnFSq:5276.581055 Lon:-122.975052 Lat:49.267075 st:2 6 RSq:0.124916 LnFSq:5276.578125 Lon:-122.97

Página 4

WikiPrint - from Polar Technologies101geort period mSet how often Geo-Route violation is checked.m = 10 to 300 Seconds to wait between each Geo-Route

Página 5

WikiPrint - from Polar Technologies102geort rcountView Geo-Route's restricted area alarm ($PGRT ALRMR messages) counter. This value is non-volati

Página 6

WikiPrint - from Polar Technologies103geort report r1 [r2] [r3] [r4] [r5] [r6] [r7] [r8]Associate up to 8 reports for Geo-Route.r1 to r8 = 0 to 999 Re

Página 7

WikiPrint - from Polar Technologies104geort th r tSet the number of consecutive violations encountered before a corresponding alarm (ALRMA/ALRMR) mess

Página 8

WikiPrint - from Polar Technologies105geort update r u [n] PáginaAdd/update Geo-Routes from specified location.Please note that previous routes with iden

Página 9

WikiPrint - from Polar Technologies106gopad nManually initiates a PAD connection on the CTM's serial port(s).n = 1 First PAD configuration (Seria

Página 10

WikiPrint - from Polar Technologies107gpsaccel n a [d]Sets the GPS report triggers using GPS based hard acceleration and deceleration events.Reports w

Página 11

WikiPrint - from Polar Technologies108gpsaddmes n m1 [m2] [m3] [m4]Adds messages to a GPS report.n = 1 to 8 GPS report numberm1 to m4Message type to b

Página 12

WikiPrint - from Polar Technologies109gpscond n b t [d] [ms Ms] [h hs] [mt]Sets the condition(s) that will trigger a GPS report.The conditional operat

Página 13

WikiPrint - from Polar Technologies11accelsensor nSpecify a sensor to use for report triggering on longitudinal acceleration.n = 0 Use accelerometer (

Página 14

WikiPrint - from Polar Technologies110gpsdataDisplays the current status of GPS input devices configured via [gpsinput] and corresponding GPS data.Exa

Página 15

WikiPrint - from Polar Technologies111gpsdelmes n mThis command is used to delete a message type (or all messages) from a GPS report.n = 1 to 8 GPS re

Página 16

WikiPrint - from Polar Technologies112gpsdgps nConfigure DGPS mode and SBAS. DGPS correction data source will be set as WAAS or RTCM.n = 0 Disables DG

Página 17

WikiPrint - from Polar Technologies113gpsemail n emailaddrSets the email address that the GPS report will be sent to.Up to 8 email addresses may be co

Página 18

WikiPrint - from Polar Technologies114gpsggaDisplays the current GPS position in NMEA0183 format.This command is a read only command.Examples:1. Retur

Página 19

WikiPrint - from Polar Technologies115gpsinput mThis command defines what source to use for GPS data.m = 1 Use internal GPS module (TSIP) (Not availab

Página 20

WikiPrint - from Polar Technologies116gpslocip n ipaddrSets the IP address of the local server that the GPS report will be sent to.Up to 8 GPS reports

Página 21

WikiPrint - from Polar Technologies117gpslocport n portSets the port number of the local server that the GPS report will be sent to.Up to 8 GPS report

Página 22

WikiPrint - from Polar Technologies118gpsmesDisplays all messages associated with each GPS report.This command is read only.Examples:1. Display all me

Página 23

WikiPrint - from Polar Technologies119gpsparam input priority port br db p sb fcThis command configures the parameters and priority of the port the mo

Página 24

WikiPrint - from Polar Technologies12agpspde ip port tm pc pl nlThis command is used to configure Assisted GPS (A-GPS) parameters on supported wireles

Página 25

WikiPrint - from Polar Technologies120gpspos n ±xx.xxxxxx ±yyy.yyyyyySet fixed GPS position mode. This sets the GPS coordinates used in modem reports

Página 26

WikiPrint - from Polar Technologies121gpsremip n iii.iii.iii.iiiSets the IP address of the remote server that the GPS report will be sent to. Up to 8

Página 27

WikiPrint - from Polar Technologies122gpsremport n xxxxxSets the IP port number of the remote server that the GPS report will be sent to.Up to 8 GPS r

Página 28

WikiPrint - from Polar Technologies123gpsrep n l r sSets the reporting type for each GPS report for the local and remote servers.n = 1 to 8 or report

Página 29

WikiPrint - from Polar Technologies124gpsrmcDisplays the current GPS position in NMEA0183 format.This command is a read only command.Examples:1. Retur

Página 30

WikiPrint - from Polar Technologies125gpssms n pppppppppp|emailaddrSets the destination of the GPS report that is sent as an SMS message.n = 1 to 8 GP

Página 31

WikiPrint - from Polar Technologies126gpstime nSet the priority of valid GPS as an external system time synchronization source.n = 0 Disabledn = 1-3Pr

Página 32

WikiPrint - from Polar Technologies127idle cond n a b cSet the Idle reporting and reset condition.n = 1 to 8 idle condition numbera = 0 idle START tri

Página 33

WikiPrint - from Polar Technologies128idle mode nSet the Idle mode for vehicle idling condition.n=0 Disables Idle calculationn=1Use OBDII/J1939 parame

Página 34

WikiPrint - from Polar Technologies129idle queryQuery the Idle time (seconds) for a vehicle with idle detection enabled.Examples:1. Query idle time :c

Página 35

WikiPrint - from Polar Technologies13apn nameThis command configures the APN(Access Point Name) for a modem.name Carrier Access Point Name (APN), eg.

Página 36

WikiPrint - from Polar Technologies130idle report n r1 [r2] [r3] [r4] [r5] [r6] [r7] [r8]This command sets the report(s) to be used for IDLE triggered

Página 37

WikiPrint - from Polar Technologies131idle resetResets the idle time to 0.Examples:1. reset idle time :cmd ctm15xcmd idle resetSee also: [Idle Time]Fi

Página 38

WikiPrint - from Polar Technologies132idle time nSet the Idle time for vehicle idling condition to start being recorded.n Idle time in secondsExamples

Página 39

WikiPrint - from Polar Technologies133igncond n aSets the condition(s) that would trigger an ignition report.The state of the ignition is controlled b

Página 40

WikiPrint - from Polar Technologies134ignreport [n] [r1] [r2] [r3] [r4] [r5] [r6] [r7] [r8]This command sets the report(s) to be used for ignition tri

Página 41

WikiPrint - from Polar Technologies135inputReads the value and state of all inputs. There are a total of six inputs on CTM200r1 and eight inputs on CT

Página 42

WikiPrint - from Polar Technologies136insetup n d x.x p aConfigures the six or eight inputs. Their use as a digital or analog input can be set along w

Página 43

WikiPrint - from Polar Technologies137ioaddmes n x [x2][x3][x4]Adds a message to an IO reportn = 1 to 8 IO report numberxmessage type to be added, val

Página 44

WikiPrint - from Polar Technologies138iocond n b t i1 i2 IP mtSets the condition(s) that would trigger an IO report.n = 1 to 8 IO report numberb = 0 c

Página 45

WikiPrint - from Polar Technologies139iodelmes n xDeletes a message (or all messages) from an IO report.n = 1 to 8 IO report numberx message type to b

Página 46

WikiPrint - from Polar Technologies14autoconnect nConfigure the modem to automatically connect to a network.n = 0 Manual network connectionn = 1 Auto

Página 47

WikiPrint - from Polar Technologies140ioemail n emailaddrSets the email address that the IO report will be sent to (if configured for email using [ior

Página 48

WikiPrint - from Polar Technologies141iolocip n iii.iii.iii.iiiSets the IP address of the local server that the IO report will be sent to. Up to 8 IO

Página 49

WikiPrint - from Polar Technologies142iolocport n xxxxxSets the port number of the local server that the IO report will be sent to. Up to 8 IO reports

Página 50

WikiPrint - from Polar Technologies143iomesDisplays all messages associated with each IO report.Notes:• This is a read only command.Examples:1. displa

Página 51

WikiPrint - from Polar Technologies144ioremip n iii.iii.iii.iiiSet the IP address of the remote server that the IO report will be sent to. Up to 8 IO

Página 52

WikiPrint - from Polar Technologies145ioremport n xxxxxSets the IP port number of the remote server that the IO report will be sent to. Up to 8 IO rep

Página 53

WikiPrint - from Polar Technologies146iorep n l r sSets the reporting type for each IO report for the local and remote servers.n = 1 to 8 IO report nu

Página 54

WikiPrint - from Polar Technologies147See also: [IO Reports]

Página 55

WikiPrint - from Polar Technologies148iosms n pppppppppp|emailaddrSets the destination of the IO report that is sent as an SMS message. Up to 8 IO rep

Página 56

WikiPrint - from Polar Technologies149ipadrQueries the IP address assigned to the modem by the wireless network.Notes:• This is a read only command.Ex

Página 57

WikiPrint - from Polar Technologies15autopevent nEnables the [$PEVENT] message to be pre-pended to any existing reports. The [$PEVENT] message contain

Página 58

WikiPrint - from Polar Technologies150ipsecShow all IPsec commands.Notes:• This is a read only command.Examples:1. show all IPsec commands :cmd ipsecS

Página 59

WikiPrint - from Polar Technologies151ipsec dpddelay nThis option activates the DPD (Dead Peer Detection) and sets the time (in seconds) allowed betwe

Página 60

WikiPrint - from Polar Technologies152ipsec dpdmaxfail nIf cmd ipsec dpddelay is set > 0, this sets the maximum number of liveliness proofs to requ

Página 61

WikiPrint - from Polar Technologies153ipsec dpdretry nIf this command is set, this sets the delay to wait for a proof of liveliness before considering

Página 62

WikiPrint - from Polar Technologies154ipsec enable nEnable/disable IPsec on the CTM-200.n = 1 enable IPsecn = 0 disable IPsecExamples:1. Enable IPsec

Página 63

WikiPrint - from Polar Technologies155ipsec ikeauth pskDefines the authentication method used for the phase 1 negotiation.Currently pre-shared key is

Página 64

WikiPrint - from Polar Technologies156ipsec ikedhgroup nDefine the IPsec IKE phase I Diffie-Hellman group.n = 1 modp768n = 2 modp1024 (default)n = 5 m

Página 65

WikiPrint - from Polar Technologies157ipsec ikeenc algDefine the IPsec IKE phase I encryption algorithm.alg = des Data Encryption Standard algorithmal

Página 66

WikiPrint - from Polar Technologies158ipsec ikeexchange modeDefine the IPsec IKE phase I exchange mode when the peer is configured as an initiator (cl

Página 67

WikiPrint - from Polar Technologies159ipsec ikehash algDefine the IPsec IKE phase I hash algorithm.alg = md5 Message-Digest algorithm 5 (MD5) hash alg

Página 68

WikiPrint - from Polar Technologies16aux dev nameThis command sets the auxiliary device name that will be sent as part of the message when in [mode 23

Página 69

WikiPrint - from Polar Technologies160ipsec ikeinitial nDefine the IPsec IKE phase I initial contact setting. Enable this to set the IPsec daemon to s

Página 70

WikiPrint - from Polar Technologies161ipsec ikelifetime nDefine the IPsec IKE phase I lifetime in seconds.n = 0 to 268435455 IKE phase 1 lifetime in s

Página 71

WikiPrint - from Polar Technologies162ipsec ikemodecfg nGather network information through ISAKMP mode configuration. Default is offn = 0 off (Default

Página 72

WikiPrint - from Polar Technologies163ipsec ikemyid type valueSpecifies the identifier sent to the remote host and the type to use in the phase 1 nego

Página 73

WikiPrint - from Polar Technologies164ipsec ikepassive nDefine the IPsec IKE phase I peer role of the modem as either initiator or responder.n = 0 set

Página 74

WikiPrint - from Polar Technologies165ipsec ikepeerid type valueSpecifies the identifier to be received from the remote host in the phase 1 negotiatio

Página 75

WikiPrint - from Polar Technologies166ipsec ikeproposal obey|strict|claim|exactSpecifies the action of lifetime length, key length, and PFS of the pha

Página 76

WikiPrint - from Polar Technologies167ipsec ikerekey on|off|forceEnable automatic renegotiation of expired phase1 when there are non-dying phase2 SAs.

Página 77

WikiPrint - from Polar Technologies168ipsec ikeverifyid nIf you want to verify the peer's identifier, set this to on. In this case, if the value

Página 78

WikiPrint - from Polar Technologies169ipsec localnet nDefines whether to use the CTM-200 eth0 or eth1 LAN ports for the local IPsec tunnel.n=0 use LAN

Página 79

WikiPrint - from Polar Technologies17aux lead c1 [c2] [c3] [c4] [c5]This command sets the leading characters for [mode 24], auxiliary interface.c1 to

Página 80

WikiPrint - from Polar Technologies170ipsec loglevel info|notify|debug|debug2Defines the IPsec logging level.info lowest log level (default)debug2 hig

Página 81

WikiPrint - from Polar Technologies171ipsec natt nEnable IPsec NAT traversal (NAT-T) setting. NAT-T allows one or both peers to reside behind a NAT ga

Página 82

WikiPrint - from Polar Technologies172ipsec nattkeepalive nSet the IPsec NAT traversal (NAT-T) keepalive interval. This is the interval between sendin

Página 83

WikiPrint - from Polar Technologies173ipsec psk iii.iii.iii.iii keySet IPsec pre-shared key used for IKE phase I.iii.iii.iii.iii = 0.0.0.0 to 255.255.

Página 84

WikiPrint - from Polar Technologies174ipsec rekey on|off|forceEnable automatic renegotiation of expired phase1 when there are non-dying phase2 SAs. Po

Página 85

WikiPrint - from Polar Technologies175ipsec remgw iii.iii.iii.iiiDefine IPsec remote gateway IP address.iii.iii.iii.iii = anonymousWhen configured as

Página 86

WikiPrint - from Polar Technologies176ipsec remnet n iii.iii.iii.iii mDefine IPsec remote subnet(s) using Classless Inter-Domain Routing (CIDR) notati

Página 87

WikiPrint - from Polar Technologies177ipsec remping nSet interval to ping a remote target specified using the [ipsec remtarget] command.n ping time in

Página 88

WikiPrint - from Polar Technologies178ipsec remtarget iii.iii.iii.iiiSpecify remote IP address to periodically ping. Ping interval is specified using

Página 89

WikiPrint - from Polar Technologies179ipsec restrict nSet restrictive access policy for IPsec applications. Enabling the restrictive access policy lim

Página 90

WikiPrint - from Polar Technologies18aux leadterm mThis command sets whether to use leading characters, terminating characters or both for [mode 24].m

Página 91

WikiPrint - from Polar Technologies180ipsec saauth algDefine the IPsec ISAKMP phase II authentication algorithm.alg = hmac_md5 Message-Digest algorith

Página 92

WikiPrint - from Polar Technologies181ipsec saenc algDefine the IPsec ISAKMP phase II encryption algorithm.alg = des Data Encryption Standard algorith

Página 93

WikiPrint - from Polar Technologies182ipsec salifetime nDefine the IPsec ISAKMP phase II lifetime in seconds.n = 0 to 268435455 ISAKMP phase II lifeti

Página 94

WikiPrint - from Polar Technologies183ipsec sapfsgroup nDefine the IPsec ISAKMP perfect forward secrecy group.n = 0 nonen = 1 modp768n = 2 modp1024 (d

Página 95

WikiPrint - from Polar Technologies184ipsec showShow IPsec configuration.Notes:• This is a read only command.Examples:1. show IPsec commands :cmd ipse

Página 96

WikiPrint - from Polar Technologies185ipsec split nEnable/disable IPsec split-tunneling on the CTM-200.n = 0 disable split-tunneln = 1 enable split-tu

Página 97

WikiPrint - from Polar Technologies186lanbridge nEnable bridging of LAN ports on CTM-200. When bridging is enabled, both LAN ports will be bridged to

Página 98

WikiPrint - from Polar Technologies187landhcp p ddd nConfigures the LAN dynamic host configuration protocol (DHCP) server settings on the CTM-200 gate

Página 99

WikiPrint - from Polar Technologies188landns p iii.iii.iii.iii [jjj.jjj.jjj.jjj]Set DNS nameserver IP address(es) for the CTM-200 LAN client interface

Página 100

WikiPrint - from Polar Technologies189lanfriends n xx:xx:xx:xx:xx:xxThis command is used to control access to PC devices connected through the CTM-200

Página 101

WikiPrint - from Polar Technologies19aux len nThis command sets the amount of bytes to read for [mode 23/24].n = 0 to 205 Bytes to read, must be great

Página 102

WikiPrint - from Polar Technologies190langw p iii.iii.iii.iiiSet default gateway IP address for the CTM-200 LAN client interfaces.p = 0 or 1 ethernet

Página 103

WikiPrint - from Polar Technologies191lanip p iii.iii.iii.iii [mmm.mmm.mmm.mmm]Sets the IP address of the CTM-200 gateway's ethernet ports.p = 0

Página 104

WikiPrint - from Polar Technologies192lannat p nEnables NAT (Network Address Translation) on the CTM-200 ethernet port(s). This configuration would be

Página 105

WikiPrint - from Polar Technologies193lannetmask p iii.iii.iii.iiiSets the netmask of the CTM-200 gateway's ethernet port on the LAN.p = 0 or 1 e

Página 106

WikiPrint - from Polar Technologies194lanproto p typeConfigure LAN interface protocol on LAN0 or LAN1 to use DHCP or a Static IP address.p = 0 or 1 La

Página 107

WikiPrint - from Polar Technologies195lanrepip iii.iii.iii.iiiSets the IP address of the local server connected to the modem?s LAN that will receive l

Página 108

WikiPrint - from Polar Technologies196lanwdnEnable / disable the LAN watchdog. The LAN watchdog is used to monitor for potential ethernet / ARP issues

Página 109

WikiPrint - from Polar Technologies197mbusm add n ip|serial*This is command is used when the CTM200 is being used as a MODBUS Master*Command is used w

Página 110

WikiPrint - from Polar Technologies198mbusm cond n b t [sid1, r1, dt1, md1, Md1] [sid2, r2, dt2, md2, Md2] [mt]*This is command is used when CTM200 is

Página 111

WikiPrint - from Polar Technologies1991. Send MODBUS Master report 2 every 60 seconds AND if register 2 of MODBUS Slave 1 is between 10 and 20 :cmd mb

Página 112

WikiPrint - from Polar Technologies2Table of Contentsaccelcond r a [d] [l] [mt] 9accelreport n r1 [r2] [r3] [r4] [r5] [r6] [r7] [r8] 10accelsensor n 1

Página 113

WikiPrint - from Polar Technologies20aux mode mSet the processing mode for [mode 23/24].m=0 Disables any processing, send raw data (Default)m=1 Parker

Página 114

WikiPrint - from Polar Technologies200mbusm data n*This is command is used when CTM200 is being used as a MODBUS Master*Show the current register valu

Página 115

WikiPrint - from Polar Technologies201mbusm del n*This is command is used when CTM200 is being used as a MODBUS Master*This command deletes one or all

Página 116

WikiPrint - from Polar Technologies202mbusm exccond e*This is command is used when CTM200 is being used as a MODBUS Master*Set the condition that will

Página 117

WikiPrint - from Polar Technologies203mbusm excreport r1 [r2] [r3] [r4] [r5] [r6] [r7] [r8]*This is command is used when CTM200 is being used as a MOD

Página 118

WikiPrint - from Polar Technologies204mbusm poll n r c [dt] [f] [o] [e]*This is command is used when CTM200 is being used as a MODBUS Master*Configure

Página 119

WikiPrint - from Polar Technologies205mbusm report n r1 [r2] [r3] [r4] [r5] [r6] [r7] [r8]*This is command is used when CTM200 is being used as a MODB

Página 120

WikiPrint - from Polar Technologies206mip nSets the Mobile IP operation of the modem. This command is only applicable to CDMA/EV-DO devices.n = 0 simp

Página 121

WikiPrint - from Polar Technologies207modbusadd id [ip|serial]*This is command is used when CTM200 is being used as a MODBUS Slave Gateway*id = 1 to 2

Página 122

WikiPrint - from Polar Technologies208modbusctm130 n*This is command is used when CTM200 is being used as a MODBUS Gateway*Enables MODBUS backward com

Página 123

WikiPrint - from Polar Technologies209modbusdel n*This is command is used when CTM200 is being used as a MODBUS Gateway*Deletes an entry or all entrie

Página 124

WikiPrint - from Polar Technologies21aux polldev nameNote: Should use aux dev if using FW 2.0.5.3358 or higherThis command sets the auxiliary device n

Página 125

WikiPrint - from Polar Technologies210modbusgw*This is command is used when CTM200 is being used as a MODBUS Gateway*Use this to initiate the MODBUS g

Página 126

WikiPrint - from Polar Technologies211modbusidmap n ip p*This is command is used when CTM200 is being used as a MODBUS Master Gateway*This command set

Página 127

WikiPrint - from Polar Technologies212modbusmode nConfigures the CTM to act as a MODBUS Master or MODBUS gateway. If configuring for MODBUS master gat

Página 128

WikiPrint - from Polar Technologies213modbusport xxxxx*This is command is used when CTM200 is being used as a MODBUS Gateway*Sets the listening port n

Página 129

WikiPrint - from Polar Technologies214modbussecure nSecure access to the modem's MODBUS server from the Internet.If enabled, it will not be possi

Página 130

WikiPrint - from Polar Technologies215mode a b cSets the required functionality of the serial ports.a The function of ttyAM0 (Primary DB9) (port 1)b T

Página 131

WikiPrint - from Polar Technologies216See also: [Serial Port Settings], [MODBUS], [PAD], [RFID Card Reader Support], [Garmin PND]

Página 132

WikiPrint - from Polar Technologies217modemid <string>Assigns a user configurable ID to the CTM-200 gateway containing up to 15 alphanumeric cha

Página 133

WikiPrint - from Polar Technologies218modemmode nConfigures the modem for "half bridge mode"This command is used to provide the connected de

Página 134

WikiPrint - from Polar Technologies219modemmodedhcp nConfigures the modem to use DHCP when configured for "half bridge mode"n = 0 modem mode

Página 135

WikiPrint - from Polar Technologies22aux polllen nNote: Should use aux len if using FW 2.0.5.3358 or higherThis command sets the amount of bytes to re

Página 136

WikiPrint - from Polar Technologies220msgredirect add xxx.xxx.xxx.xxx yyyyyAdd a redirect target used by the message redirector.xxx.xxx.xxx.xxx = 0.0.

Página 137

WikiPrint - from Polar Technologies221msgredirect del xxx.xxx.xxx.xxx yyyyyDelete a redirect target used by the message redirector.xxx.xxx.xxx.xxx = 0

Página 138

WikiPrint - from Polar Technologies222msgredirect enable nEnables/disables the message redirector on the CTM-200. The message redirector redirects inc

Página 139

WikiPrint - from Polar Technologies223msgredirect listDisplay a list of redirect targets configured for the message redirector.Examples:1. List curren

Página 140

WikiPrint - from Polar Technologies224msgredirect port xxxxxConfigure listening port used by the message redirector. Packets arriving on this UDP port

Página 141

WikiPrint - from Polar Technologies225msgredirect remip xxx.xxx.xxx.xxxRestrict the message redirector to redirect incoming messages originating from

Página 142

WikiPrint - from Polar Technologies226multiwan enable nEnable/disable multiwan configurationn = 0 disable (default)n = 1 enableExamples:1. Enable mult

Página 143

WikiPrint - from Polar Technologies227multiwan mode mSet multiwan mode type. Multiwan mode types can be used to configure special packet routing confi

Página 144

WikiPrint - from Polar Technologies228netwd t n target p mSets the network watchdog feature.This feature is used to listen for incoming data traffic t

Página 145

WikiPrint - from Polar Technologies229networktime nSet priority of cellular network time as an external system time synchronization source.n = 0 Disab

Página 146

WikiPrint - from Polar Technologies23aux pollnowThis command tells CTM to poll/listen to the auxiliary device when in [mode 23].Examples:1. To poll th

Página 147 - See also: [IO Reports]

WikiPrint - from Polar Technologies230nmeamode nSets the NMEA 0183 version that applies to the GPS message format for GPGLL, GPRMC, and GPVTG sentence

Página 148

WikiPrint - from Polar Technologies231ntpserver urlSet the network time protocol (NTP) server used by the modem's built-in NTP client for externa

Página 149

WikiPrint - from Polar Technologies232ntptime nSet priority of the built-in network time protocol (NTP) client as an external system time synchronizat

Página 150

WikiPrint - from Polar Technologies233obdcond n b t mt [trig1 ... trig4]Sets the condition(s) that will trigger an OBD report.n = 1 to 8 OBD trigger n

Página 151

WikiPrint - from Polar Technologies234See Also: [OBD2/J1939 Parameters Table], [Engine Diagnostics Support]

Página 152

WikiPrint - from Polar Technologies235obddataDisplays the current OBD engine parameters and corresponding values obtained from the OBDII transmitter a

Página 153

WikiPrint - from Polar Technologies236obdreport n r1 [r2] [r3] [r4] [r5] [r6] [r7] [r8]This command sets the report(s) to be used for a OBD triggered

Página 154

WikiPrint - from Polar Technologies237obdsp nSets the protocol used by the OBDII transmitter.n = 0 Automaticn = 1 SAE J1850 PWMn = 2 SAE J1850 VPWn =

Página 155 - See also: [IPsec]

WikiPrint - from Polar Technologies238odometer nSets/queries the odometer.The odometer keeps track of the distance travelled in km by using GPS (cmd c

Página 156

WikiPrint - from Polar Technologies239orientation nSet device mounting orientation within the vehicle when using the accelerometer.Orientation Code De

Página 157

WikiPrint - from Polar Technologies24aux pollstr strThis command sets the polling string that is sent if configured when cmd aux pollnow is executed w

Página 158

WikiPrint - from Polar Technologies240n = 19Standing on a short edge away fromGPIO connector which is locatedtowards the rear of the vehicle-X -Zn = 2

Página 159

WikiPrint - from Polar Technologies241otaspThis command is used to perform automatic wireless network activation and updates any required network rela

Página 160

WikiPrint - from Polar Technologies242padList all PAD configuration commands.Notes:• On CTM devices that support multiple serial ports the second PAD

Página 161

WikiPrint - from Polar Technologies243pad clientport portSets the default client PAD port number for use with dialup emulationport = 0 to 65535 dialup

Página 162

WikiPrint - from Polar Technologies244pad echo nSets the PAD echo mode ? if echo is enabled then all data sent to the modem on its RS232 port by an ex

Página 163

WikiPrint - from Polar Technologies245pad esc strSets the PAD escape sequence used to return to command line mode.strPAD escape sequence, 10 character

Página 164

WikiPrint - from Polar Technologies246pad esct nSets the PAD escape guard time.This is the idle time before and after the PAD escape sequence which mu

Página 165

WikiPrint - from Polar Technologies247pad fifo nSets the internal communication mechanism used by PAD.n = 0 Use a serial port directly for PAD communi

Página 166

WikiPrint - from Polar Technologies248pad fwdc x rSets the PAD forwarding character and to remove the forwarding character before forwarding the packe

Página 167

WikiPrint - from Polar Technologies249pad fwdl xx = 0 send every characters immediatelyx = 1 to 1000 maximum PAD packet length (default 40)Examples:1.

Página 168

WikiPrint - from Polar Technologies25aux polltim n [f]This command sets the timeout for each polling command when polling in [mode 23].In [mode 23], a

Página 169

WikiPrint - from Polar Technologies250pad fwdt tt = 0 Disable forwarding timer. Every character will be sent immediatelyt = 1 to 255 PAD forwarding ti

Página 170

WikiPrint - from Polar Technologies251pad ip ipaddrSets the remote PAD IP address.ipaddr = 0.0.0.0 to 255.255.255.255 remote IP address. (Default 0.0.

Página 171

WikiPrint - from Polar Technologies252pad mode xSets the PAD mode.x = 0start up UDP PAD mode. The modem will revert to server mode once theconnection

Página 172

WikiPrint - from Polar Technologies253pad pfc xSets the PAD postfix character that is added at the end of each packetx = none Disabled (default). No c

Página 173

WikiPrint - from Polar Technologies254pad port pSets the remote PAD port number.This is the listening port if the modem is in PAD server mode.p = 0 to

Página 174

WikiPrint - from Polar Technologies255pad resetResets the PAD connection.Notes:• The actions taken by this command are to drop the PAD connection and

Página 175

WikiPrint - from Polar Technologies256pad secure nSecure access to the modem's PAD server from the Internet.If enabled, it will not be possible t

Página 176

WikiPrint - from Polar Technologies257pad svct n [c]Sets the PAD server connection timeout.If no data is sent or received within this timeout value, t

Página 177

WikiPrint - from Polar Technologies258panicreportack tThis command will set the modem to wait for a Pendant panic triggered report (PANIC or MPANIC me

Página 178

WikiPrint - from Polar Technologies259panicreport r1 [r2] [r3] [r4] [r5] [r6] [r7] [r8]This command will set the report(s) to be used for pendant trig

Página 179

WikiPrint - from Polar Technologies26aux report r1 [r2] [r3] [r4] [r5] [r6] [r7] [r8]This command sets the report(s) to be used for auxiliary interfac

Página 180

WikiPrint - from Polar Technologies260panicreportack tThis command will set the modem to wait for a Pendant panic triggered report (PANIC or MPANIC me

Página 181

WikiPrint - from Polar Technologies261panicreptype mThis command will set whether panicreport will generate ASCII/NMEA message (e.g. $PPEN,0013A200402

Página 182

WikiPrint - from Polar Technologies262pendantreport r1 [r2] [r3] [r4] [r5] [r6] [r7] [r8]This command sets the general report(s) to be used for pendan

Página 183

WikiPrint - from Polar Technologies263pin nSets the 4-digit PIN code to lock the SIM card used with cell devices. A 4-digit PIN code is required outsi

Página 184

WikiPrint - from Polar Technologies264ping n iii.iii.iii.iii|websiteConfigures the modem to ping a specific IP address or website periodically.n = 0 D

Página 185

WikiPrint - from Polar Technologies265pobdx n1 [n2] [n3] [n4] [n5] [n6] [n7] [n8]Configures the engine - vehicle diagnostic report messages. See [Repo

Página 186

WikiPrint - from Polar Technologies266port n r d p s fConfigures the baud rate and data format of the specified serial port.n = 1 configure Primary DB

Página 187

WikiPrint - from Polar Technologies267pppProvide the connected device a PPP connection through the serial port.Notes:• To escape from this mode and re

Página 188

WikiPrint - from Polar Technologies268pswd nSets the password used for wireless network access via simple IP. This is often set to the electronic seri

Página 189

WikiPrint - from Polar Technologies269pupcond n aSets the condition(s) that would trigger a power up report.n = 1 to 8 power up condition numbersa = 0

Página 190

WikiPrint - from Polar Technologies27aux reptim nThis command sets the reporting frequency when in [mode 23/24].n = 0 Send report when data received (

Página 191

WikiPrint - from Polar Technologies270pupreport n r1 [r2] [r3] [r4] [r5] [r6] [r7] [r8]This command sets the report(s) to be used for power-up trigger

Página 192

WikiPrint - from Polar Technologies271pwr accelt aConfigure the CTM-200's wake up condition for acceleration based on internal accelerometer.a =

Página 193

WikiPrint - from Polar Technologies272pwr geofence lat lon rad modeConfigure the CTM-200 gateway to wake up based on a geofence.lat center point latit

Página 194

WikiPrint - from Polar Technologies273pwr mode nControls the CTM-200?s power mode.n = 1 puts the gateway in standby moden = 2 will power cycle the gat

Página 195

WikiPrint - from Polar Technologies274pwr override mConfigure the CTM-200 gateway to prevent entering minimum power mode for the current session.m = 0

Página 196

WikiPrint - from Polar Technologies275pwr rtc u mConfigure the CTM-200's wake up condition based on RTC time.u UTC time of first wakeup (default

Página 197

WikiPrint - from Polar Technologies276pwr sdwn a dddddPlaces the CTM-200 gateway into shutdown mode or minimum power mode (blinking power LED) based o

Página 198

WikiPrint - from Polar Technologies277pwr speedth s tConfigure the CTM-200's wake up condition based on GPS speed.s = 0 to 254 speed threshold in

Página 199

WikiPrint - from Polar Technologies278pwr temp l h mConfigure the CTM-200's wake up condition for temperature.l Low threshold in degrees Celsius

Página 200

WikiPrint - from Polar Technologies279pwr vcct vv.v tControls the supply voltage below which the CTM-200 gateway will automatically go into standby mo

Página 201

WikiPrint - from Polar Technologies28aux term c1 [c2] [c3] [c4] [c5]This command sets the termination characters for [mode 22/24], auxiliary interface

Página 202

WikiPrint - from Polar Technologies280pwr woe m t1 t2 t3 fConfigures what event will wake up the CTM-200 gateway (see list of wake up events below) an

Página 203

WikiPrint - from Polar Technologies28115 00008000 Wake on Man Down Pendant [wpan stm 1]16 00010000 Wake on input 7 [insetup]17 00020000 Wake on input

Página 204

WikiPrint - from Polar Technologies282ratesel nSets the required network rate mode (CDMA vs. EV-DO) of the device. This command is not valid for GSM/G

Página 205

WikiPrint - from Polar Technologies283ratetmr nSets the required network rate test timer of the device. This is used to configure the modem to test fo

Página 206

WikiPrint - from Polar Technologies284repaddmes n x [x2][x3][x4]Adds a message type to a report.n = 1 to 999 report numberx1 to x4message type to be a

Página 207

WikiPrint - from Polar Technologies285repdelmes n xThis command is used to delete a message type (or all messages) from a report.n = 1 to 999 report n

Página 208

WikiPrint - from Polar Technologies286repemail n emailaddrSets the email address that the report will be sent to (if configured for email using [repty

Página 209

WikiPrint - from Polar Technologies287repfiledelivery n t rt username server-path portDeliver file based reports to an SSH server via SCP.n = 1 to 999

Página 210

WikiPrint - from Polar Technologies288repfiledir local-pathSets the main folder for file-based reportinglocal-pathfolder for data files generated for

Página 211

WikiPrint - from Polar Technologies289repfilename n nameSets the file prefix used for a file-based report.n = 1 to 999 report numbername file prefix t

Página 212

WikiPrint - from Polar Technologies29boomreport r1 [r2] [r3] [r4] [r5] [r6] [r7] [r8]This command sets the report(s) to be used for boom-tracker trigg

Página 213

WikiPrint - from Polar Technologies290repfileout local-pathSets the outbox folder for file-based reportinglocal-pathoutbox folder for data files gener

Página 214

WikiPrint - from Polar Technologies291repfilesize kbSets the maximum file size for file-based reportingkb = 1-1024 maximum file size in KB (Default 10

Página 215

WikiPrint - from Polar Technologies292repfiletimestamp nSets the timestamp added to data files for file-based reporting.n = 0 No Timestamp addedn = 1

Página 216

WikiPrint - from Polar Technologies293repfilezip cEnables or disables the ability to compress data files generated by the file-based reporting system

Página 217

WikiPrint - from Polar Technologies294replocip n iii.iii.iii.iiiSets the IP address of the local server connected to the modem?s LAN that the report w

Página 218

WikiPrint - from Polar Technologies295replocport n xxxxxSets the port number of the local server that the report will be sent to.n = 1 to 999 report n

Página 219

WikiPrint - from Polar Technologies296reportscripts nThis command enables custom scripts to be triggered when reports are generatedn = 0 disable custo

Página 220

WikiPrint - from Polar Technologies297repremip n iii.iii.iii.iiiSets the IP address of the remote server that the report will be sent to.n = 1 to 999

Página 221

WikiPrint - from Polar Technologies298repremport n xxxxxSets the IP port number of the remote server that the report will be sent to.n = 1 to 999 repo

Página 222

WikiPrint - from Polar Technologies299repsms n pppppppppp|emailaddrSets the destination of the report that is sent as an SMS message.n = 1 to 999 repo

Página 223

WikiPrint - from Polar Technologies3dyndns user password domain 68emailsrv ip 69enghours n 70enghrmode n 71esn 72ethernet n 73event add event_descript

Página 224

WikiPrint - from Polar Technologies30bt console nEnables/disables Bluetooth console mode.n = 0 Disable Bluetooth console mode (Default)n = 1 Enable Bl

Página 225

WikiPrint - from Polar Technologies300reptype n l r sSets the reporting type for local and remote servers.n = 1 to 999 report numberl = 0 disables loc

Página 226

WikiPrint - from Polar Technologies3011. Send report #4 as a UDP packet over Ethernet and over the wireless link, and will not store reports :cmd rept

Página 227

WikiPrint - from Polar Technologies302rfonThis command is used to reset the RF switch status to its default state with the RF cell device enabled.The

Página 228

WikiPrint - from Polar Technologies303rfstatsQuery various RF statisticsNotes:• This is a read-only commandExamples:1. Query RF statistics :cmd rfstat

Página 229

WikiPrint - from Polar Technologies304rfswitch xThis command is used to enable or disable the RF switch feature on the CTM-200.The RF switch feature i

Página 230

WikiPrint - from Polar Technologies305rmtssh nEnables or disables remote SSH access to the modem.If enabled, it will be possible to access the modem w

Página 231

WikiPrint - from Polar Technologies306rmttelnetThis command configures the modem to respond to incoming telnet commands over the wireless network.The

Página 232

WikiPrint - from Polar Technologies307rmtweb nEnables or disables remote access to the embedded web server feature of the modem.If enabled, it will be

Página 233

WikiPrint - from Polar Technologies308rssiThis command queries to the current wireless network signal strength seen by the modem for both its Primary

Página 234

WikiPrint - from Polar Technologies309saltreport r1 [r2] [r3] [r4] [r5] [r6] [r7] [r8]This command sets the report(s) to be used for the chlorobyte sa

Página 235

WikiPrint - from Polar Technologies31bt enable nEnables/disables Bluetooth Dongle.n = 0 Disable Bluetooth function (Default)n = 1 Enable Bluetooth fun

Página 236

WikiPrint - from Polar Technologies310sat enable nControl satellite availability.n = 0 Disable and power off satellite (Default)n = 1 Enable and power

Página 237

WikiPrint - from Polar Technologies311sat flushClears outbound satellite messages.Examples:1. Clear outbound satellite messages.cmd ctm15xcmd sat flus

Página 238

WikiPrint - from Polar Technologies312sat force nBitmapped value selecting what type of message will force satellite ISU to power ON. Used with cmd sa

Página 239

WikiPrint - from Polar Technologies313sat ip iii.iii.iii.iiiConfigure remote server's IP to send messages received over satellite to, as well as

Página 240

WikiPrint - from Polar Technologies314sat mt nSet minimum time between identical report numbers.n = 0 to 65535 Minimum time in minutes (Default 10)Exa

Página 241

WikiPrint - from Polar Technologies315sat port xxxxxConfigure remote server's port to send messages received over satellite to, as well as to rec

Página 242

WikiPrint - from Polar Technologies316sat pwr nControl satellite availability when using cmd sat enable 2.n = 0 Disable satellite (Default)n = 1 Enabl

Página 243

WikiPrint - from Polar Technologies317sat resetResets satellite tx/rx counter to 0.Examples:1. Reset transmission counter.cmd ctm15xcmd sat resetSee a

Página 244

WikiPrint - from Polar Technologies318sat statsQuery various satellite statisticsNotes:• This is a read-only commandExamples:1. Query satellite statis

Página 245

WikiPrint - from Polar Technologies319satbackup b bt g gt oSets the option to switch to a backup satellite modem if the cellular network?s coverage is

Página 246

WikiPrint - from Polar Technologies32bt locip ipaddrSets the Bluetooth NAP IP address of bnep0 port.ipaddr = 0.0.0.0 to 255.255.255.255 Bluetooth NAP

Página 247

WikiPrint - from Polar Technologies320cmd saveSave modem configuration to non-volatile memory.Notes:• A single cmd save should be entered after a seri

Página 248

WikiPrint - from Polar Technologies321sendreport n x [x2][x3][x4]Sends a "One-Shot" report instantly. If a report already exists, the conten

Página 249

WikiPrint - from Polar Technologies322showconfig [-quiet emailaddr]Returns the current configurations of the CTM-200 gateway.Notes:• cmd showconfig wi

Página 250

WikiPrint - from Polar Technologies323showstateReturns the current state of the modem.Notes:• This is a read only command.showstate returns the modem

Página 251

WikiPrint - from Polar Technologies324sms enable nThis command configures the CTM-200 to accept SMS commands.n = 0 Disable SMS configuration accessn =

Página 252

WikiPrint - from Polar Technologies325sms friends n pppppppppppThis command is used to allow SMS messages only from phone numbers manually specified.

Página 253

WikiPrint - from Polar Technologies326sms fwdreport r1 [r2] [r3] [r4] [r5] [r6] [r7] [r8]This command sets the report(s) to be used for forwarding inc

Página 254

WikiPrint - from Polar Technologies327smssendUsed to send the previously setup SMS messageNote:• SMS features are only available for specific manufact

Página 255

WikiPrint - from Polar Technologies328smstext string delimiterUsed to enter the text message of the SMS.string text message(max 166 chars)delimiterseq

Página 256

WikiPrint - from Polar Technologies329smsto ppppppppppThis command is used to set the phone number of the SMS text message to be sent.ppppppppppphone

Página 257

WikiPrint - from Polar Technologies33bt locname nameSets the local Bluetooth device name. The remote Bluetooth device should search this device name i

Página 258

WikiPrint - from Polar Technologies330smsviewQuery the message entered via [smstext] command.Note:• SMS features are only available for specific manuf

Página 259

WikiPrint - from Polar Technologies331snfdelay t rssiThis command sets the store-and-forward delay time and minimum signal strength (RSSI) required be

Página 260

WikiPrint - from Polar Technologies332snfflushFlushes and resets store and forward NVRAM.Notes:• This command may have to be entered multiple times be

Página 261

WikiPrint - from Polar Technologies333snflog n | allUsed to display the contents of the store and forward (SNF) database locally thru a serial console

Página 262

WikiPrint - from Polar Technologies334snfonsd nThis command configures the CTM-200 to use internal or external storage (microSD) for TCP store and for

Página 263

WikiPrint - from Polar Technologies335snmp nThis command configures the CTM-200 to respond to incoming simple network management protocol (SNMP) reque

Página 264

WikiPrint - from Polar Technologies336spc nnnnnnThis command is used to enter the modem?s CSL (Client Subsidy Lock) as part of the network activation

Página 265

WikiPrint - from Polar Technologies337speedth s tSets the speed threshold for automatically enabling the RF module of the modem when it has been previ

Página 266

WikiPrint - from Polar Technologies338sshkey dss | rsaGenerate a SSH public/private key pair.dss Generate a 1024 bit DSS key pairrsa Generate a 1024 b

Página 267

WikiPrint - from Polar Technologies339sshport portSets the port for ssh access (both local and remote).port = 1 to 65535 port to be used for ssh (defa

Página 268

WikiPrint - from Polar Technologies34bt locname pinSets the local Bluetooth device password. The remote Bluetooth device should use this password when

Página 269

WikiPrint - from Polar Technologies340sshtimeout nSets the timeout period for a ssh session with no activity.n = 0 to 65535 timeout time, in seconds (

Página 270

WikiPrint - from Polar Technologies341stm upgrade f [u] [n] PáginaUpdates the CTM200's Mini Micro FW. The "cmd stm upgrade" command requir

Página 271

WikiPrint - from Polar Technologies342swipegpio nSets the GPIO row to be used.n = 0 Use GPIO's top row (inputs 3/5 and outputs 1/3)(default)n = 1

Página 272

WikiPrint - from Polar Technologies343swipeidThis command queries query the ID of the last swiped card.The swipe ID is read only and cannot be altered

Página 273

WikiPrint - from Polar Technologies344swipemode nSets the swipe card interface to be used with the modem.n = 0 Serial HID swipe card interface (defaul

Página 274

WikiPrint - from Polar Technologies345swipereport r1 [r2] [r3] [r4] [r5] [r6] [r7] [r8]This command sets the report(s) to be used for swipe card reade

Página 275

WikiPrint - from Polar Technologies346syslog nProvides a mechanism to retrieve the log of system events recorded by the modem.n = 0 to 65535number of

Página 276

WikiPrint - from Polar Technologies347taipchecksum nEnables/disables checksum in Trimble ASCII Interface Protocol messages. Checksum field will be use

Página 277

WikiPrint - from Polar Technologies348taipid DDDDSets Trimble ASCII Interface Protocol ID. TAIP ID will be used in GPS TAIP [PV]/[LN] message.DDDD a f

Página 278

WikiPrint - from Polar Technologies349taipuseid nEnables/disables reporting of ID in Trimble ASCII Interface Protocol messages. TAIP ID will be used i

Página 279

WikiPrint - from Polar Technologies35bt nap nEnables/disables Bluetooth Network Access Point mode. A NAP can act as a bridge between Bluetooth network

Página 280

WikiPrint - from Polar Technologies350tcppersist nThis command configures the CTM-200 to maintain persistent TCP connections for configured TCP report

Página 281

WikiPrint - from Polar Technologies351telnetport nSets the port for telnet access (both local and remote).n = 1 to 65535 port to be used for telnet (d

Página 282

WikiPrint - from Polar Technologies352telnetpswd nSets password for telnet access (both local and remote) and ssh access (both local and remote).n max

Página 283

WikiPrint - from Polar Technologies353telnettimeout nSets the timeout period for a telnet session with no activity.n = 0 to 65535 timeout time in seco

Página 284

WikiPrint - from Polar Technologies354timesync tSet the period in seconds when the modem's system time and the power management controller's

Página 285

WikiPrint - from Polar Technologies355timezone tzSet the system timezone.tz a valid timezone from this list [timezones].Examples:1. Set timezone to PS

Página 286

WikiPrint - from Polar Technologies356universal nEnable/disable universal card mode override.n = 0 Disable universal card moden = 1 Enable universal c

Página 287

WikiPrint - from Polar Technologies357univwd m url/reportConfigure the Universal Watchdog.m = 0 disabledm = 1 detect increase in received packets.m =

Página 288

WikiPrint - from Polar Technologies358univwdtimer n pSets the timer value for the universal watchdog timer.n = 1 to 65535 watchdog timer interval in s

Página 289

WikiPrint - from Polar Technologies359upgradefw imagefile.tar url username passwdRemote upgrade of the firmware (kernel and root filesystem images).im

Página 290

WikiPrint - from Polar Technologies36bt obd nEnables/disables Bluetooth OBD mode.n = 0 Disable Bluetooth OBD mode (Default)n = 1 to 8Enable Bluetooth

Página 291

WikiPrint - from Polar Technologies360upgradesrv a.a.a.aThis command is used to set the IP address of a remote client that is authorized to run remote

Página 292

WikiPrint - from Polar Technologies361usepeerdns nThis command is used to enable or disable the CTM-200 gateway from obtaining its DNS nameserver IP a

Página 293

WikiPrint - from Polar Technologies362user nameSets the username used for wireless network access via simple IP. This is often in the format of [phone

Página 294

WikiPrint - from Polar Technologies363vccReturns the current value of the modem?s supply voltage.Notes:• This is a read only command.Examples:1. Query

Página 295

WikiPrint - from Polar Technologies364vcccond n o [a.a] [mt]This command is used to set the condition(s) that would trigger a supply voltage level rep

Página 296

WikiPrint - from Polar Technologies365vccreport n r1 [r2] [r3] [r4] [r5] [r6] [r7] [r8]This command sets the report(s) to be used for supply voltage l

Página 297

WikiPrint - from Polar Technologies366verQueries the currently installed firmware version of the modem.Examples:1. Query the current firmware version

Página 298

WikiPrint - from Polar Technologies367vpnc nEnable the VPNC vpn client applicationn = 0 Disabled (Default)n = 1 EnableExamples:1. Enable VPNC vpn clie

Página 299

WikiPrint - from Polar Technologies368vue ack stringConfigure VUE service to send an acknowledgement string to the VUE device management server.string

Página 300

WikiPrint - from Polar Technologies369vue period nConfigure the time period (in minutes) for the device to run VUE client, the CTM client management a

Página 301

WikiPrint - from Polar Technologies37bt remname n nameSets the remote Bluetooth device name to search for when pairing with remote Bluetooth device.n

Página 302

WikiPrint - from Polar Technologies370vue port nConfigure TCP server port for device used when VUE service is run in server mode.n = 1 to 65535 TCP po

Página 303

WikiPrint - from Polar Technologies371vue pwrup nConfigure VUE client to run after device power up.n = 0 disabledn = 1 enabled (default)Examples:1. Se

Página 304

WikiPrint - from Polar Technologies372vue remip a.a.a.aConfigure IP address of remote VUE server. When the VUE service is run in client mode, this com

Página 305

WikiPrint - from Polar Technologies373vue remport nConfigure TCP port number of remote VUE server used when VUE service is run in client mode.n = 1 to

Página 306

WikiPrint - from Polar Technologies374vue service nConfigure VUE service to support remote device management from a VUE server. The CTM device communi

Página 307

WikiPrint - from Polar Technologies375wifi ap|client channel nSet the wifi channel for client or access point (AP)ap|client configure ap or clientn =

Página 308

WikiPrint - from Polar Technologies376wifi ap|client country country-codeSet the regulatory domain for wifi radio communications.ap|client configure A

Página 309

WikiPrint - from Polar Technologies377wifi ap|client encryption enctypeSet wireless connection encryption typeap|client configure AP or clientenctype

Página 310

WikiPrint - from Polar Technologies378wifi ap|client hwmode modeSet the hardware mode for the wifi radio.ap|client : configure AP or clientmode : mode

Página 311

WikiPrint - from Polar Technologies379wifi ap|client key pre-shared-keySet the pre-shared-key for an encrypted wifi configuration.ap|client configure

Página 312

WikiPrint - from Polar Technologies38bt rempin n pinSets the remote Bluetooth device password to use to pair with the remote device defined in bt remn

Página 313

WikiPrint - from Polar Technologies380wifi macThis command can be used to query the MAC address of the CTM-200 wireless radio.Examples:1. Query MAC ad

Página 314

WikiPrint - from Polar Technologies381wifi radiusport nSet the port number for a wifi Radius authentication servern = 0 to 65535 Radius server port nu

Página 315

WikiPrint - from Polar Technologies382wifi radiusserver iii.iii.iii.iiiSet the IP address for a wifi Radius authentication serveriii.iii.iii.iii = 0.0

Página 316

WikiPrint - from Polar Technologies383wifi ap|client ssid SSIDSet the SSID for the wifi connection.ap|client : configure AP or clientSSID SSID of wire

Página 317

WikiPrint - from Polar Technologies384wifi watchdog n [t]Enable/disable wifi watchdog.n=0 disable watchdogn=1 enable watchdogt=31 to 65535 Watchdog th

Página 318

WikiPrint - from Polar Technologies385wlan dns ipaddrSet a DNS namerserver IP address for the CTM-200 wifi client interface (WLAN).ipaddr = 0.0.0.0 to

Página 319

WikiPrint - from Polar Technologies386wlan enable nConfigure CTM cell/wi-fi operation moden = 0 Cell onlyn = 1 Cell + Wifi Clientn = 2 Cell + Wifi Acc

Página 320

WikiPrint - from Polar Technologies387wlan gw ipaddrSet a default gateway IP address for the CTM-200 wifi client interface (WLAN).ipaddr = 0.0.0.0 to

Página 321

WikiPrint - from Polar Technologies388wlan ip ipaddrSet a static IP address for the CTM-200 gateway's wifi client interface (WLAN).ipaddr = 0.0.0

Página 322

WikiPrint - from Polar Technologies389wlan netmask iii.iii.iii.iiiSets the netmask of the CTM-200 gateway's wifi client interface (WLAN).iii.iii.

Página 323

WikiPrint - from Polar Technologies39can applyForce re-configuration of STM with values set in [cmd can engparam] and [cmd can prot].Examples:1. Confi

Página 324

WikiPrint - from Polar Technologies390wlan proto typeDefine the network protocol for the CTM-200 wifi client interface (WLAN) to use DHCP or static IP

Página 325

WikiPrint - from Polar Technologies391wpan acktype typeAssigns an acknowledgment type for the Work Alone system.There are two acknowledgment types:typ

Página 326

WikiPrint - from Polar Technologies392wpan adddev xx-xx-xx-xx-xx-xx-xx-xxAdds a WPAN device ID to the CTM-200?s registered WPAN devices list. Up to 16

Página 327

WikiPrint - from Polar Technologies393wpan delallDeletes all WPAN device IDs from the CTM-200?s registered WPAN devices list.Examples:1. Delete all WP

Página 328

WikiPrint - from Polar Technologies394wpan deldev xx-xx-xx-xx-xx-xx-xx-xxDeletes a WPAN device ID from the CTM-200?s registered WPAN devices list.xx-x

Página 329

WikiPrint - from Polar Technologies395wpan dist nn = 0 disable distance report message (default)n = 1 enable distance report message for PANIC, MPANIC

Página 330

WikiPrint - from Polar Technologies396wpan panid xxxxSet the WPAN PAN ID to communicate with the WPAN devices.xxxx WPAN PAN ID (hex digits) (default 4

Página 331

WikiPrint - from Polar Technologies397wpan pensrv x yyyyConfigure the listening protocol and port of the Pendant Server that provides remote access to

Página 332

WikiPrint - from Polar Technologies398wpan secure nSecure access to the CTM-200's WPAN Pendant Server from the Internet.n = 0 Allow direct access

Página 333

WikiPrint - from Polar Technologies399wpan stm nConfigure the CTM-200 to use the internal WPAN Gatewayn = 0 do not use internal WPAN Gateway (default)

Página 334

WikiPrint - from Polar Technologies4idle time n 132igncond n a 133ignreport [n] [r1] [r2] [r3] [r4] [r5] [r6] [r7] [r8] 134input 135insetup n d x.x p

Página 335

WikiPrint - from Polar Technologies40can enghours nDetermines the source of engine hours value returned by cmd enghours. If enghrmode is not 0, this c

Página 336

WikiPrint - from Polar Technologies400wpanpanid xxxxSet the WPAN PAN ID to communicate with the WPAN devices.xxxx WPAN PAN ID (hex digits)Using wpanpa

Página 337

WikiPrint - from Polar Technologies41can engparam mDefines which parameters are to be queried/reported.m Hexadecimal bit maskbit = 0 Not usedbit = 1 t

Página 338

WikiPrint - from Polar Technologies42can odometer nDetermines the source of odometer value returned by cmd odometer.n = 0 Odometer calculated by CTM b

Página 339

WikiPrint - from Polar Technologies43can prot pEnables/disables internal CAN and sets the protocol to be used as follows:p = 0 CAN disabled (Default)p

Página 340

WikiPrint - from Polar Technologies44can psthruid n idConfigure specific CAN header/ID to look for (J1939/OBD2) when using canpsthru ps.n = 1 to 8 Sup

Página 341

WikiPrint - from Polar Technologies45can psthrumin n mtMinimum time between CAN data for a specific header/ID when using canpsthru ps. If mt is not re

Página 342

WikiPrint - from Polar Technologies46can qryrate nSets the maximum querying rate for OBD.n = 0 to 18000 Querying rate in 100ms units (Default 2)Exampl

Página 343

WikiPrint - from Polar Technologies47cardlistclearRemoves list of approved swipe-card IDs from modem.Examples:1. cmd cardlistclearSee also: [RFID Card

Página 344

WikiPrint - from Polar Technologies48cardlistload filename url [username] [passwd]This loads the approved ID list used with the swipe card interface f

Página 345

WikiPrint - from Polar Technologies49cardlistsaveProcess and store a list of approved swipe-card IDs for use by CTM and bootloader swipe card reader a

Página 346

WikiPrint - from Polar Technologies5lanrepip iii.iii.iii.iii 195lanwdn 196mbusm add n ip|serial 197mbusm cond n b t [sid1, r1, dt1, md1, Md1] [sid2, r

Página 347

WikiPrint - from Polar Technologies50cardlockload lock-script-file-name url [username] [passwd]This command is used to load the custom lock script ass

Página 348

WikiPrint - from Polar Technologies51cardunlockload unlock-script-file-name url [username] [passwd]This command is used to load the custom unlock scri

Página 349

WikiPrint - from Polar Technologies52clientmac nn:nn:nn:nn:nn:nnUse clientmac to set the 12-digit hexadecimal MAC address of a client computer Etherne

Página 350

WikiPrint - from Polar Technologies53confdropWhen used, this command will look for the following configuration file: /tmp/ctm200-config.tgzNotes:• All

Página 351

WikiPrint - from Polar Technologies54confupgrade script-name url [username] [passwd]Configures the modem for over-the-air configuration by means of a

Página 352

WikiPrint - from Polar Technologies55ctm15xThis command is used to enable a reset of protected configuration values.Current protected configuration co

Página 353

WikiPrint - from Polar Technologies56data [0]This command keeps track of the amount of data transmitted and received over the wireless data link.Notes

Página 354

WikiPrint - from Polar Technologies57datacond xThis command is used to set the condition that will trigger wireless link data count report(s). Report(

Página 355

WikiPrint - from Polar Technologies58datareport r1 [r2] [r3] [r4] [r5] [r6] [r7] [r8]This command sets the report(s) to be used for link data count tr

Página 356

WikiPrint - from Polar Technologies59device cell typeConfigure the wireless cellular data device used by the CTM.Notes:• Default = NONEExamples:1. Con

Página 357

WikiPrint - from Polar Technologies6panicreptype m 261pendantreport r1 [r2] [r3] [r4] [r5] [r6] [r7] [r8] 262pin n 263ping n iii.iii.iii.iii|website 2

Página 358

WikiPrint - from Polar Technologies60device cellnetwork nConfigure cell device to use a specified network type.Note:This command is only supported on

Página 359

WikiPrint - from Polar Technologies61device cellnetwork nConfigure cell device to use a specified network type.n = DEFAULT Use network type already se

Página 360

WikiPrint - from Polar Technologies62device priority nA CTM configured for dual-mode (cell + wifi client, or cmd wlanenable 1), also requires a specif

Página 361

WikiPrint - from Polar Technologies63device wifi typeConfigure the wifi device type installed in the CTM.type = NONE No wi-fi device (Default)type = A

Página 362

WikiPrint - from Polar Technologies64dir pppppppppp [qqqqqqqqqq]This command sets the NAM (Number Assignment Module) value for the modem. It is a 10-d

Página 363

WikiPrint - from Polar Technologies65dmz ipThis command is used to set up the demilitarized zone (DMZ) feature of the modem that will let all packets

Página 364

WikiPrint - from Polar Technologies66dnscheck nThis command is used to enable or disable the CTM gateway from checking for valid DNS IP addresses obta

Página 365

WikiPrint - from Polar Technologies67dout n x [d]This command is used to set the state of each of the outputs. There are four outputs in total for CTM

Página 366

WikiPrint - from Polar Technologies68dyndns user password domainConfigure the CTM gateway device to perform regular updates to the Dynamic Domain Name

Página 367

WikiPrint - from Polar Technologies69emailsrv ipThis command is used to set the IP address of the SMTP email server that will be used by the modem for

Página 368

WikiPrint - from Polar Technologies7sms friends n ppppppppppp 325sms fwdreport r1 [r2] [r3] [r4] [r5] [r6] [r7] [r8] 326smssend 327smstext string deli

Página 369

WikiPrint - from Polar Technologies70enghours nQuery and set the total engine hours. When a modem is installed in a vehicle and the current vehicle en

Página 370

WikiPrint - from Polar Technologies71enghrmode nMethod of obtaining engine hours.n = 0Disabled (Default). Engine hours can still be obtained if vehicl

Página 371

WikiPrint - from Polar Technologies72esnThis command queries the serial number of the embedded wireless network access device.Notes:• The ESN/IMEI is

Página 372

WikiPrint - from Polar Technologies73ethernet nThis command is used to enable or disable the Ethernet services of the modem.n = 0Disable Ethernet serv

Página 373

WikiPrint - from Polar Technologies74event add event_description [log-level]Manually add an event to the event log. Added events can be reported as we

Página 374

WikiPrint - from Polar Technologies75event dump [-f N | -h N] [-l N | -t N] [-raw] [EVENT_FILTER] [email@address]displays the event log with Unix time

Página 375

WikiPrint - from Polar Technologies76event healthinterval nDefine the interval (seconds) between HEALTH status reports.n = 600 to 86400 Number of seco

Página 376

WikiPrint - from Polar Technologies77event logclearClears the event log file.Examples:1. Clear event log :cmd event logclearSee also: [Diagnostics and

Página 377

WikiPrint - from Polar Technologies78event dump [-f or -h N] [-l or -t N] [-raw] [EVENT_FILTER] [email@address]displays the event log with Unix timest

Página 378

WikiPrint - from Polar Technologies79event loglevel min maxSet the event reporting level, events within the specified min/max range will be reported u

Página 379

WikiPrint - from Polar Technologies8wlan gw ipaddr 387wlan ip ipaddr 388wlan netmask iii.iii.iii.iii 389wlan proto type 390wpan acktype type 391wpan a

Página 380

WikiPrint - from Polar Technologies80SET_FUEL_RATE:<resetbyign> <deltadistance><deltatime> OK|FAIL4cmd fuel rate <resetbyign>

Página 381

WikiPrint - from Polar Technologies81event minoffline nSets the minimum time interval (seconds) before reporting a CELL_ONLINE event. By increasing th

Página 382

WikiPrint - from Polar Technologies82eventreport r1 [r2] [r3] [r4] [r5] [r6] [r7] [r8]Report event log events.r1 to r8 = 0 Disables the report (Defaul

Página 383

WikiPrint - from Polar Technologies83firewall n extport locport t ip sThis command is used to setup the port forwarding configuration of the modem.n =

Página 384

WikiPrint - from Polar Technologies84freeconsoleKill the serial console shell process. This command must be done at first if you use [gopad] or [modbu

Página 385

WikiPrint - from Polar Technologies85friends n ip netmask [t]This command is used to setup the modem's firewall friends list, which is used to bl

Página 386

WikiPrint - from Polar Technologies86ftp remote nEnable/disable remote ftp access to the CTM.n = 0 Disable remote ftp (Default)n = 1 Enable remote ftp

Página 387

WikiPrint - from Polar Technologies87ftp server nEnable/disable the CTM FTP server.n = 0 Disable ftp server (Default)n = 1 Enable ftp serverNotes:• Pu

Página 388

WikiPrint - from Polar Technologies88fuel io n x y zConfigures the total fuel calculation to use GPIO inputs.n = 1 to 6 GPIO used (Default 1)x = 0 to

Página 389

WikiPrint - from Polar Technologies89fuel mode nSet the fuel calcuation method.n = 0 Disables fuel calculation (Default)n = 1Use OBDII MAF (mass air f

Página 390

WikiPrint - from Polar Technologies9accelcond r a [d] [l] [mt]Set acceleration trigger condition.r = 1 to 8 Acceleration report numbera = 0 Longitudin

Página 391

WikiPrint - from Polar Technologies90fuel queryQuery the total fuel used (liters) in a vehicle with fuel calculation enabled.Examples:1. Query the fue

Página 392

WikiPrint - from Polar Technologies91fuel rate i d tSets whether timer or distance or both triggers when fuel rate is calculated. Whenever d or t trig

Página 393

WikiPrint - from Polar Technologies92fuel rate queryQuery the fuel rate value.Notes:• This command will return ERROR if the minimum distance set by [f

Página 394

WikiPrint - from Polar Technologies93fuel rate resetResets the fuel rate value to 0.Examples:1. Resets the fuel rate :cmd fuel rate resetSee also: [Fu

Página 395

WikiPrint - from Polar Technologies94fuel resetResets the fuel value to 0.Examples:1. Reset the fuel value.cmd ctm15xcmd fuel resetSee also: [Fuel Rat

Página 396

WikiPrint - from Polar Technologies95geort acountView Geo-Route's exited allowed area alarm ($PGRT ALRMA messages) counter. This value is non-vol

Página 397

WikiPrint - from Polar Technologies96geort c2bin [-d]Convert text-based route list stored in /etc/geort/rt into a CTM binary format. '-d' fl

Página 398

WikiPrint - from Polar Technologies97geort delete routeDeletes Geo-Routes from active routes.route = ALL Delete ALL routesroute = 1 to 32 Geo-Route to

Página 399

WikiPrint - from Polar Technologies98geort enable nDisable or enable Geo-Route.n = 0 Geo-Route disabled (Default)n = 1 Geo-Route enabledExamples:1. To

Página 400

WikiPrint - from Polar Technologies99geort list [n | -w]Display Geo-Routes being monitored.n = 1 to 32 View midpoints for route n-w Print list in wide