Cypress STK11C68-5 Manual do Utilizador Página 9

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 15
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 8
STK11C68-5 (SMD5962-92324)
Document Number: 001-51001 Rev. *A Page 9 of 15
AutoStore INHIBIT or Power Up RECALL
Parameter Alt Description
STK11C68-5
Unit
Min Max
t
HRECALL
[9]
t
RESTORE
Power up RECALL Duration 550 μs
t
STORE
t
HLHZ
STORE Cycle Duration 10 ms
V
SWITCH
Low Voltage Trigger Level 4.0 4.5 V
V
RESET
Low Voltage Reset Level 3.6 V
Figure 10. AutoStore INHIBIT/Power Up RECALL
V
CC
V
SWITCH
V
RESET
POWER-UP RECALL
DQ (DATA OUT)
STORE INHIBIT
5V
t
HRECALL
POWER-UP
RECALL
BROWN OUT
STORE INHIBIT
NO RECALL
(V
CC
DID NOT GO
BELOW V
RESET
)
BROWN OUT
STORE INHIBIT
NO RECALL
(V
CC
DID NOT GO
BELOW V
RESET
)
BROWN OUT
STORE INHIBIT
RECALL WHEN
V
CC
RETURNS
ABOVE V
SWITCH
Notes
9. t
HRECALL
starts from the time V
CC
rises above V
SWITCH
.
[+] Feedback
Vista de página 8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

Comentários a estes Manuais

Sem comentários