Suprex® Remote
Relay 3 IN
Input Signal
(5Volts DC
Maximum)
Contact
Outputs
Relay 3 N.O.!
Relay 3 Com!
Relay 3 N.C.
Suprex® Central
Relay 3 functions as an Alarm relay and monitors the condition of the communication link between !
the Central and Remote units. Relay 3 is activated when power is applied and the communication link between
the Central and Remote is functioning. Relay 3 will become deactivated (Alarm condition)!
when either the Relay 3 input on the remote is active OR the Remote unit is unable to communicate with the
Central unit. See APP NOTE FOR DETAILS
Relay 4 N.O.!
Relay 4 Com!
Relay 4 N.C.
Suprex® Remote
Contact
Outputs
Relay 4 IN
Input Signal
(5Volts DC
Maximum)
Suprex® Central
Red arrow denotes direction
of command signal