© 2009 Cypress Solutions PAD Operation (Revision 1.0)
15 Technical Support/Warranty
cmd padmode 4/5 PAD client, persistent mode: 4 = UDP, 5 = TCP
cmd padip 200.100.1.1 Sets IP address of remote server handling data reported by the field device
cmd padport 8000 Sets port to which data is to be sent
cmd padecho 0 Do not echo data sent by the field device back on the serial port
cmd padfwdc 13 Decimal value of ASCII <CR> (default setting, in effect after cmd factory)
cmd padfwdl 40 Data to be sent over the air in 40-byte packets or less if <CR> in first 40 bytes
(default setting, in effect after cmd factory)
cmd padfwdt 20 Sets the forwarding time to 1 second idle period
(default setting, in effect after cmd factory)
cmd padsvct 15 0 Set connection timeout to 15 seconds, maximum connection timer is disabled
(default settings, in effect after cmd factory)
cmd save Save configuration to modem’s non-volatile memory
cmd pwrmode 2 Power cycle
6 Technical Support/Warranty
Cypress Solutions Service
Support Group
1.877.985.2878 or 604.294.4465
9.00am to 5.00pm PST