Input
Red arrow denotes direction!
of command signal
Relay 3 Input and Output
Output
Relay 3 functions as an Alarm relay and monitors the condition of the communication link between the
Central and Remote units. Relay 3 is activated when power is applied and the communication link
between the Central and Remote is functioning. Relay 3 will become deactivated (Alarm condition)"
when either the Relay 3 input on the remote is active OR the Remote unit is unable to communicate
with the Central unit.
Suprex Operation and Initial Setup
I/O Controls
*
12-RLY2 N.O."
11-RLY2 Com"
10-RLY2 N.C."
9-RLY1 N.O."
8-RLY1 Com"
7-RLY1 N.C."
6-RS232 Out"
5-RS232 In"
4-Ground"
3-Aux In"
2-N/C"
1-N/C"
Remote Unit
2-8 to 16 VDC In"
1-Ground
8-485(+)"
7-485(-)"
6-+5 VDC Out"
5-RLY4 Input (5V)"
4-RLY3 Input (5V)"
3-LED Output"
2-D1/Data/F2F Input"
1-D0/CLK Input
*
Central Unit
2-8 to 16 VDC In"
1-Ground
8-485(+)"
7-485(-)"
6-+5 VDC Out"
5-Prog Res 2"
4-Prog Res 1"
3-LED Input"
2-D1/Data/F2F Out "
1-D0/Clock Out
12-RLY4 N.O."
11-RLY4 Com"
10-RLY4 N.C."
9-RLY3 N.O."
8-RLY3 Com"
7-RLY3 N.C."
6-RS232 Out"
5-RS232 In"
4-Ground"
3-Aux Out"
2-Relay2 Input"
1-Relay1 Input"